@letsbetechs: Now for the repair on that pain-in-the-ass leak. ​The best part of editing footage from two months ago is getting to call myself out for half-assing the homestretch. In my defense, it was boiling hot, late in the day, and I still had a one-hour drive to get home. Nobody’s perfect. 😂😂 ​If another leak pops up in this piping, the whole lineset is getting replaced. I wasn't thrilled with how far apart those original supports were, or the only support I could find in the van to use, but it’ll hold up. ​#hvac #hvacapprentice #hvactechnician #hvaclife #refrigeration

Lets Be Techs
Lets Be Techs
Open In TikTok:
Region: US
Saturday 29 August 2026 12:00:35 GMT
27006
1687
110
42

Music

Download

Comments

beener97
Dillon Beene :
That Mountain Dew custom refrigerant line brace is at least 2k minimum
2026-08-29 14:31:01
44
josejorgecastillo0
Jose Jorge Castillo :
ooh easy. it leaking because its 5mm copper ad not 7mm and its more susceptible to leaking like the new coils
2026-08-31 05:01:33
0
dennisstetler
DennisinNC :
Hot gas defrost stretched the pipe. Seen it before.
2026-08-30 09:20:31
1
mystical_smoke420
mysticalsmoke420 :
improper support gave ya a good ol stress fractrure what a fun leak to find
2026-08-29 12:10:11
17
assgephoenix
AssgeePhoenix :
HVAC is a Profession where even small things should be made to high standards Couse on this field nothing is impossible .That was an improper insulation problem that's why when joining amaflex one should put one piece on top of the other Couse if you do straight joint if water brake a leak on the amaflex that's wher most of the water will move to and metal purity is affected at that point this resulting in a Decay and eventually a leak
2026-08-30 18:37:28
2
micahks
micahks :
How you like the navac gauges? Better than field piece?
2026-08-30 12:26:42
1
princelothar
Prince Lothar :
🤣 i have seen this before. Please understand I know how this happens. You see the insulation covered the pipe. The installer used a blade to cut the installation. While doing this, he cut the pipe after time. The pipe split
2026-08-29 13:42:04
24
zacherymb
ZacheryMB :
Can you just put in a sharkbite? 😂
2026-08-30 12:31:46
1
yonela.aphendule
Yonela aphendule :
why you working alone can I be your assistant I have 4 years in the trade not qualified am in south Africa
2026-08-30 13:28:12
1
joshuaojudah1234
Judah :
you have got some nice toys
2026-08-29 23:41:35
1
ashto2021
Ash Ash :
that pipe had it lifespan. needs to replace.
2026-08-30 03:32:58
1
primalcurve
lol k :
do you have to be cautious about using nitrogen in a closed environment like that?
2026-08-29 13:48:19
1
lonley_star_slowly_dying
Tiredandlost1106 :
That nitrogen regulator is awesome. I've never seen one with a braze setting.
2026-08-29 15:30:46
1
jeffmontalvo529
jeffm :
my only concern was during the leak confirmation it seemed like the bubble leak check was being pulled into the system which would contaminat the refrigerant. I personally wouldn't have pumped down because of the risk
2026-08-29 13:06:40
4
maintenance.man.h
Maintenance Man Herb :
new wedding band!
2026-08-29 18:22:41
1
ticttok24
dennishess24 :
THIS GUY IS GOOD
2026-08-29 16:23:00
1
jon_roebux
Jon roebux :
What brand was that Schrader tool?
2026-08-29 12:44:53
1
matt.1110
matt :
Electrician here, is there no code for horizontal pipe support? For us it’s at least every meter, vibrations on top of someone cutting that insulation to the pipe is what I’m thinking happened
2026-08-29 15:06:25
1
justinreilly95
justinreilly95 :
as always myself and my team enjoy watching someone else do what we do everyday. We primarily do refrigeration in the Charlotte NC area and surroundings. Thanks for sharing your experiences and giving others the opportunity to see what techs do for customers that goes unseen.
2026-08-29 12:38:45
5
stonedhyena2
Brodog :
Where did you get that nitrogen regulator? That’s neat!!
2026-08-29 18:06:37
1
4lols1985
4lols1985 :
Is it too long a space between the supports and it’s been flexing?
2026-08-29 18:04:14
1
billyworthington80
Billy Worthington :
Wonder if the armaflex glue caused that over time?
2026-08-29 15:49:00
1
reamer98
Jeffrey :
I got a question for you, Boss even after you sanded it I’m noticing that the copper is severely pitted. My guess is gonna be the VOC gases are extremely high. Eating away at the copper during moisture production.
2026-08-29 22:32:31
1
thepiratetrucker
Pirate Trucker :
Love your content, and interacting is supposed to help you. I know why it’s leaking….. has a hole in it. You’re welcome 😁. Keep them coming
2026-08-29 22:25:57
1
skellypop69
Tik Toker :
Isnt there a lawsuit against a certain insulation brand because it cause the pipes to leak like this?
2026-08-29 17:28:36
3