@chicon.services: How to install a WATER TANK #buildingrepairs #buildingtech #foryourepage #plumbing

CHICON Services
CHICON Services
Open In TikTok:
Region: JM
Sunday 30 August 2026 18:08:08 GMT
17767
236
72
150

Music

Download

Comments

bryangraham223
Bryan be good :
2 pipe system is best way
2026-08-30 21:15:18
4
ryf_thebossy
ERROL DBOSSY :
🔥sir stop misleading the people 🔥 learn this 🔥one line up to tank 1/2" Tee🔥check valve arrow out to divert water upwards 🔥1/2" Union to service the Tank 1"lock off for service🔥addition 1/2" Check valve over the water meter then water filter🔥service the water filter and not the tank🔥thank me later
2026-08-30 20:21:49
0
musalewis23
musalewis23 :
one pipe for more than 16 years hasn't service not for that time
2026-08-30 20:46:04
1
plumber_man2
Chris :
That is foolishness. One pipe can work just as good as two, you have to rephrase that argument.
2026-08-30 21:30:25
2
triplet5082
triplet the capable :
servicing a check valve every 6 months is bullshit..
2026-08-30 20:02:15
1
javoodoo
😈UnRuly😈 :
dem get what dem pay fah
2026-08-30 19:48:35
3
truthbetold5964
TruthBeTold :
And it is such a common set up
2026-08-30 19:28:44
3
capo01107
capo :
yes you can all you have to do is add a second one-way value on the main supply line so water can only flow in and not out when the supply line water pressure drop or cut off
2026-08-30 20:14:51
1
michealallen2
Michael Allen :
one pipe works perfectly fine once every 6 months check valve change you are wrong with that get a easy flow check valve
2026-08-31 04:17:28
0
d.oracle5
D oracle :
same way how dem climb the roof to install the lock off 🤣🤣🤣. they can have 2 lock offs tho
2026-08-30 19:57:27
0
andybless54
andybless :
LET ME PUT THIS IN CAPS. YOUR TANK FILLING UP ON THE ROOF DEPENDS ON THE WATER PRESSURE COMING FROM NWC MAIN SOURCE
2026-08-30 21:16:26
0
bowensmarlonking
kane :
you can use one pipe
2026-08-31 02:22:38
0
delanoymhenry0
delanoyahshawnmar :
Money him a look😂😂😂 6 months have a check value on commercial building and it’s working over 3 years now
2026-08-31 02:12:15
0
ricky.mitchell1
Ricky Mitchell :
🤔 ... it works great ...with less materials 3 none return valves needed...1 at the exit 1 one the inlet and one where the meter or the main enters the premises then put a float check value in the tank
2026-08-30 23:33:53
0
claytonwhyte
mr mint car rental :
total foolishness
2026-08-31 00:28:10
0
chross29
Courtney Chross :
I totally agree
2026-08-30 21:04:54
3
gary.morrison311
Gary Morrison :
😂😂😂😂😂😂😂
2026-08-31 02:33:49
0
triplet5082
triplet the capable :
all this narrator is trying to do is scare you to do more work and spend more money!!!
2026-08-30 22:18:08
1
triplet5082
triplet the capable :
the only thing I'd give a agreement with in this video is the 2 pipe setup..... but also understand it's the same setup, just a longer way around!!!
2026-08-30 22:19:55
0
alex.johnson4760
Alex Johnson :
I am out of plumbing for about 4 years an I am telling u 1 pipe can work...did many before I leave Jamaica an they still working an which non return value u use that need to be change r service every 6 month? bro not bashing u bec we all can learn from each other but don't mess lead ppl like that....
2026-08-31 05:18:03
0
cob710
Clive (Bryan's Maintaince ) :
tell them bro
2026-08-31 02:40:49
1
dean.kelly29
dean kelly :
Mi a nuh plumber and mi see seh that a bs 🙄
2026-08-31 04:58:55
0
odanerowe8
Odane RuleBreaker :
1 pipe do the work just that I would rather to use metal ball value and a metal swing check value
2026-08-31 01:54:42
0
aquarium.designs360
$🇯🇲Raymond D. Johnson🇯🇲$ :
Simply. put a one way check valve and the service entry point. use one pipe with a one way check valve at the base to service the hous. tap into the one pipe to the top end of the tank with a float valve to service the tank. note the direction of the valve arrow.
2026-08-31 01:40:48
0