@sisal.engineering: the way I was insulted me. 😂 hm

Sisal engineering
Sisal engineering
Open In TikTok:
Region: GH
Monday 31 August 2026 23:42:23 GMT
13344
441
35
30

Music

Download

Comments

engkilonzi_
PRIME ENGINEER KILONZI :
most columns are designed to take compressive load rather than tension sir. buckling occurs at 0.5L for fixed-fixed supports. so lapping can never occur at column midpoint.
2026-09-03 13:48:15
8
vannably4
Khalid Budu :
But buckling risk is high at the middle. so basically the column over there, it lapping is wrong. please, can you explain further
2026-09-02 13:36:48
2
holiday3919
holiday :
Does that meaan lapping needs to be done the middle of column??
2026-09-01 12:32:13
1
civiliansaidi
Saed :
Did you miss the lecture of buckling
2026-09-02 16:43:16
2
achimbonczek
covirax1024 :
Please send another video without the writing covering the whole explanation zone.
2026-09-01 09:54:06
4
richmondyeboah8
Richmond Yeboah :
meaning we are doing the wrong thing all this while
2026-09-01 08:03:14
3
muhammadhussain19027
Colonel0068 :
shear zone bro not tension zone
2026-09-01 18:11:06
1
sly80727
sly :
Pls are u able to do another video to show us clearly de right lapping zone cus we can hardly see what you are trying to show us. I understand what you are explaining but we need more clarity with pictorial evidence. At what height is de lapping acceptable? Thanks
2026-09-01 06:23:08
2
kweku_danquah
Kweku Danquah :
very true. dense stirrups at the bar and top.
2026-09-02 18:11:07
1
samshupe
Sam shupe :
so this lapping is wrong? please can you show a video of a good lapping?
2026-09-02 06:45:31
1
alpha_mode38
Tony :
This is correct for short columns with with moments at the ends. We lap and provide sufficient lap length at the bottom because it is easy to construct. However if the column is slender, the maximum moment due to slenderness may occur in the centre depending on the end conditions and it is not advisable to lap in the centre. An effective way to provide the rebar is to stagger them.
2026-09-03 16:06:21
2
evansapam8
Apam Evans Mascot :
Please, if I did not use, a starter pillar and I want to lab it at the top what would be the cause or effect and encase in that situation how many floors can I go with this ?
2026-09-05 04:13:14
0
brooklyjnr
YOUNG ING 🦺🏗 :
Please can u Lap continues column in the middle of the starter column???
2026-09-02 10:45:49
1
smoda_
SMODA :
so where's the proper lapping zone sir? Are you suggesting the lapping should be done at the middle of the starter column?
2026-09-05 23:33:05
1
komlatv
AFRICAN MAGICAL HERBS :
engineer please what about the welded steels. does it follow same principle?
2026-09-01 07:40:51
1
kilobyte2t
kilo byte :
pls show us d correct one
2026-09-01 06:21:12
1
mushpiano
mushPiano/Civil.Tech :
usually at 1/4L
2026-09-03 12:28:28
1
i.a.muda
M^I^A :
You’re 100% right
2026-09-01 10:40:58
1
de.rock230
De Rock :
my role model
2026-10-08 11:56:39
0
thunder.awawu
Thunder Awawu :
Mmmm?
2026-10-04 20:37:38
0
indigonovember
Indigo November :
tension??? happens only in lateral loads, eccentric loads. it distribute the laps at different heights for each bar. also it looks like an internal column so I'm confused to what is being said here
2026-09-15 06:01:04
0
mrcrown17
SOV :
Omo this is wrong and besides ur text is covering the correct site practice
2026-09-13 15:25:30
0
zion.architect1
Arc/engr Stephen Akwagiobe :
if u know u know if u don't know no comment
2026-09-04 14:19:24
0
michaelquaye15
Michael Quaye :
hmm😏
2026-09-04 08:43:51
0
retrofitengineering
retrofitengineering :
1/3 and 2/3
2026-09-04 08:37:40
0
To see more videos from user @sisal.engineering, please go to the Tikwm homepage.

Other Videos


About