most columns are designed to take compressive load rather than tension sir. buckling occurs at 0.5L for fixed-fixed supports. so lapping can never occur at column midpoint.
2026-09-03 13:48:15
8
Khalid Budu :
But buckling risk is high at the middle. so basically the column over there, it lapping is wrong. please, can you explain further
2026-09-02 13:36:48
2
holiday :
Does that meaan lapping needs to be done the middle of column??
2026-09-01 12:32:13
1
Saed :
Did you miss the lecture of buckling
2026-09-02 16:43:16
2
covirax1024 :
Please send another video without the writing covering the whole explanation zone.
2026-09-01 09:54:06
4
Richmond Yeboah :
meaning we are doing the wrong thing all this while
2026-09-01 08:03:14
3
Colonel0068 :
shear zone bro not tension zone
2026-09-01 18:11:06
1
sly :
Pls are u able to do another video to show us clearly de right lapping zone cus we can hardly see what you are trying to show us. I understand what you are explaining but we need more clarity with pictorial evidence. At what height is de lapping acceptable? Thanks
2026-09-01 06:23:08
2
Kweku Danquah :
very true. dense stirrups at the bar and top.
2026-09-02 18:11:07
1
Sam shupe :
so this lapping is wrong? please can you show a video of a good lapping?
2026-09-02 06:45:31
1
Tony :
This is correct for short columns with with moments at the ends. We lap and provide sufficient lap length at the bottom because it is easy to construct.
However if the column is slender, the maximum moment due to slenderness may occur in the centre depending on the end conditions and it is not advisable to lap in the centre. An effective way to provide the rebar is to stagger them.
2026-09-03 16:06:21
2
Apam Evans Mascot :
Please, if I did not use, a starter pillar and I want to lab it at the top what would be the cause or effect and encase in that situation how many floors can I go with this ?
2026-09-05 04:13:14
0
YOUNG ING 🦺🏗 :
Please can u Lap continues column in the middle of the starter column???
2026-09-02 10:45:49
1
SMODA :
so where's the proper lapping zone sir? Are you suggesting the lapping should be done at the middle of the starter column?
2026-09-05 23:33:05
1
AFRICAN MAGICAL HERBS :
engineer please what about the welded steels. does it follow same principle?
2026-09-01 07:40:51
1
kilo byte :
pls show us d correct one
2026-09-01 06:21:12
1
mushPiano/Civil.Tech :
usually at 1/4L
2026-09-03 12:28:28
1
M^I^A :
You’re 100% right
2026-09-01 10:40:58
1
De Rock :
my role model
2026-10-08 11:56:39
0
Thunder Awawu :
Mmmm?
2026-10-04 20:37:38
0
Indigo November :
tension??? happens only in lateral loads, eccentric loads. it distribute the laps at different heights for each bar. also it looks like an internal column so I'm confused to what is being said here
2026-09-15 06:01:04
0
SOV :
Omo this is wrong and besides ur text is covering the correct site practice
2026-09-13 15:25:30
0
Arc/engr Stephen Akwagiobe :
if u know u know if u don't know no comment
2026-09-04 14:19:24
0
Michael Quaye :
hmm😏
2026-09-04 08:43:51
0
retrofitengineering :
1/3 and 2/3
2026-09-04 08:37:40
0