@ts050207:

t&s
t&s
Open In TikTok:
Region: ET
Tuesday 01 September 2026 06:48:58 GMT
28868
1630
95
71

Music

Download

Comments

user9569504735763
asnakew@electrical :
aykatelim Whay Because There Is Fuse After Transfermer It Open And Protect Z Trans
2026-09-01 11:46:34
6
sure2049
Sure :
If the transformer remains overloaded: Overload → higher current → much higher heat → insulation deterioration → winding damage → possible transformer failure. A short-term overload may be acceptable if the transformer manufacturer allows it and the temperature remains within limits. But continuous overloading is dangerous. Also, transformer capacity is normally specified in kVA, not simply kW, because the winding current—and therefore heating—depends on apparent power. If you give me your transformer rating (e.g., 500 kVA), primary/secondary voltage, and actual load in amps or kW, I can calculate exactly how much you are overloading it and estimate the effect.
2026-09-01 16:00:43
7
engineering.com64
Engineering.com :
what is the difference of KVA AND KV
2026-09-01 14:39:48
0
fishta4
Fish :
አዳዲስ ቆጣሬዎች ፓወር ሲበዛ እና ሲቀንስ በራሱ ጊዜ ይጠፋል መብራት ሀይል ሰራተኞች ምንም አይነት መፍቴ ሊያመጡልን አልቻሉም ችግሩ ምን ሊሆን ይችላል?
2026-09-02 04:19:25
2
eth04.71
@Ethio.My country :
ባጭሩ "Overload →Higher current→ I^2R losses →Heat → Insulation aging→ Failure. if the overload becomes severe enough, you can eventually get: "Insulation breakdown→turn-to-turn short circuit→very high fault current→transformer failure/burning"
2026-09-02 03:20:34
2
mattabera
mateyasaabera :
no, calculation only answers on paper it don't consider human error, manufacturing error and environmental factors. engineering is not calculation only, it's also trial and error. to answer your question overload means over current flow that increase the temperature in the wire Which leads to fail or distroy the insulation on the wire leading to destroy the transformer. Please show us the simple calculation you talked about?
2026-09-01 14:30:58
2
gracewills38
Graceb38 :
Excessive load spikes Joule heating (P=I^2R) melting the winding enamel via extreme thermal stress. Bare copper then triggers a phase-to-phase short, dumping massive fault current and welcome to 💥
2026-09-01 19:42:29
2
s.balageru12
s balageru@12 :
አንች ግን ማሪያምን ትለያለሽ
2026-09-01 16:21:44
3
desalegn.biza8
desalegn biza :
overlod dayrctly attack fuse.
2026-09-01 17:58:43
2
esuyesuf
E.A.Y :
A transformer burns out primarily when excessive heat breaks down its internal insulation, causing a short circuit or catastrophic failure.🙏
2026-09-02 13:03:34
1
electromechanical.et
SOLVE IT🌍 :
ቲዎሪ እና ፎሙላ ለምህንድስና ስራ መመሪያ እንደሆኑ አይካድም። ነገር ግን ሁሉም ፎርሙላዎች የሚሰሩት 'ፍጹም በሆነ ሁኔታ' (Ideal Conditions) ላይ ተመስርተው ነው። በተጨባጭ የስራ ቦታ ላይ ግን ፎርሙላ ውስጥ የሌሉ እንደ ሙቀት፣ ንዝረት፣ እርጥበት እና የቮልቴጅ መዋዠቅ ያሉ በርካታ ተፅዕኖዎች አሉ። በልምድ የሚሰሩ ሰዎች ደግሞ እነዚህን ያልተጠበቁ ችግሮች በተግባር የመፍታት እና ስራውን እውን የማድረግ ትልቅ አቅም አላቸው። ልምድ ላንች ምንድን ነው🤔
2026-09-02 08:01:24
4
user4216362629495
world pc :
und curent and voltage
2026-09-08 18:27:54
0
massadama5
Mass-Adama :
ለማነኛውም ትራንፎርመር አይቃጠልም ነበር። ነገር ግን እሚቃጠለው EEU HRC Protection Fuse size ከትራንስፎርመሩ አቅም ጋር የተመጣጠነ አይደለም። eg: 50 Kva Trafo 250A HRC Fuse ይጠቀማሉ። በዚህ ወቅት ይቃጠላል። ነገር ግን የሚቃጠልብት ምክንያቶች 1. Protection sm 2. Over Load 3. HRC Fuse Rated 4. Cooling Oil Resistance Rated 5. Over Temperature 6. and etc
2026-09-02 19:34:43
2
tigerman1519
@ elec -tewe@ 15 19⚽🌏 :
ሴት electrical ሳይ እንዴት ደስ indemilegn 💋💋💋
2026-09-05 17:31:10
0
bammab9611
bogaleabebe628 :
እና አብረን እንስራው እና ከረንቱ ከኔ እሰቶሬጁ ካንቺ
2026-09-01 10:16:55
1
melegnawe0
melegnawe :
ማስረዳቱን ላንቺ
2026-09-01 07:04:52
0
esuyesuf
E.A.Y :
ከመጠን በላይ ጭነት (Overloading)፦ ትራንስፎርመሩ ሊሸከመው ከሚችለው መጠን በላይ የኤሌክትሪክ ፍሰት (current) መሳብ፣ በጊዜ ሂደት የኮይሉን (coil) መከላከያ ሽፋን (insulation) የሚያበላሽና እንዲሰነጠቅ የሚያደርግ ቀጣይነት ያለው ሙቀት ይፈጥራል።
2026-09-02 13:04:58
3
samuelbirhanu06
samuelbirhanu06 :
lemin mebirat hail agebim
2026-09-02 16:18:03
0
user7832224261519
ወርቅ:ነህ። :
ከትምርቱ ስድቡ በዛ
2026-09-02 17:35:26
0
habtamu0889
habtamu :
Transformer is step / up step down
2026-09-08 14:29:39
0
miracle_m4
Tik Toker :
ትክክል ነሽ ትራንስፎርመር አክሰሰሪዎችን በስንስረአት ከተጠቀምን ትራንስፎርመር አይቃጠልም ምኽንያቱም የ Overloud ችግር ከ HRC Fuse ከያልፍም ነገር ግን ከስታንዳርድ ውጭ ከተጠከምንበት ትራንስፎርመሩ ይቃጠላል ለምሳሌ ትራንስፎርመሩ ባለ 100KV ከሆን እኛ የምነጠከመው HRC Fuse rate ከ 63A እስከ 100A መሆን አለበት ግን ከዛበላይ ከተጠቀምን ለምሳሌ ባለ 100KV ትራንስፎርመር ለይ ባለ 200A HRC Fuse ከተጠቀምን ወይም ዳሬክት ከተጠቀምን ትራንስፎርመሩ ፌል ያደርጋል.....
2026-09-11 16:35:35
0
user8305162627922
Wondimu Gezahegn :
p =kvA
2026-09-09 16:52:30
0
buze12728
buze@#12 :
corte
2026-09-03 17:10:57
0
haftaihailu1221
Haftay Hailu :
እውነት ነው 👍
2026-09-01 09:49:44
0
To see more videos from user @ts050207, please go to the Tikwm homepage.