@electri_cal: What Happens When 230V Supply Connects 208V Windings? What happens when a 208V three-phase motor is connected to a 230V supply in star configuration? In a star-connected motor, each winding receives the line voltage divided by 3. A 208V supply applies approximately 120V to each winding, while 230V applies nearly 133V. This higher voltage-to-frequency ratio increases magnetic flux and may drive the motor core toward saturation, causing magnetizing current, winding temperature and insulation stress to rise sharply. How voltage divides across windings in star connection V Why 208V line voltage produces 120V per winding V Why 230V produces approximately 133V per winding / How excessive voltage increases magnetic flux V Why core saturation causes current and heat to rise How prolonged overvoltage can damage motor insulation Disclaimer: This video is for educational purposes only. A 208V-rated motor will not necessarily burn immediately at 230V; the result depends on its nameplate ratings, frequency, load, service factor, voltage balance, operating time and manufacturer specifications. Always follow the motor connection diagram and consult a qualified electrician. #electrical #learn #foryou #motor
Electrical
Region: AE
Tuesday 01 September 2026 11:43:26 GMT
Music
Download
Comments
Buzz2lips :
this video is wrong. the motor will run cooler at 240 volts than at 208 volts. less amps for the same load.
2026-09-02 23:32:54
16
David Log :
testing motors rated for 208v I used a step down transformer as I only had 230v available. No issues. Motors were only rated for 208v. Newer motors run on 208 and 230v. Check plate on motor.
2026-09-07 06:29:45
1
dyndas58 :
both are fine.
usuall click bait BS
2026-09-03 04:27:52
23
denzel :
So we’re not gonna talk about frequency
2026-09-06 22:20:12
0
alfarvzctuw :
This video is quite correct, although 208volts is strange and not very common. Simply, exceed the nameplate voltage by 10% with no added protection and this will happen.
2026-09-03 08:18:04
4
CC :
it's wired for 208
coils in saturation
2026-09-02 23:18:09
0
vinividivici 🇨🇦 :
try following the nameplate ratings and forget all your hypotheticals
2026-09-04 11:01:49
3
spikeboy732 :
230 is a universal voltage for 208 or 240
2026-09-04 00:06:20
1
mattsteiner01 :
It’s hard to explain this, but 230 is more than 208
2026-09-03 23:40:41
1
bendiggler :
lack of flux capacitor
2026-09-03 04:25:26
0
Cynidio :
aint got enuf coppahs in the windings, mang. needs moah coppahs!
2026-09-03 13:29:51
1
get salty 2 :
all are builds are 480v 3 ph.and 208v 3ph. some of our motors data plates are 3 ph. 208,230 or 460v on one motor.
2026-09-04 00:25:13
2
Carlos Arredondo226 :
European power 50 HZ
2026-09-03 03:53:05
1
Sar1lIIlLaiIl :
I ran a 208v garage heater on 240 for years with no problem
2026-09-03 20:15:41
3
TJ :
I’ll explain why because that’s not a motor. It’s and alternator
2026-09-02 23:50:36
0
OLD LOCUST TREE :
Usually a motor controller used in these situations!
2026-09-02 21:08:00
1
robertweyrich632 :
Amps are amps higher voltage less draw
2026-09-02 18:36:13
4
David Swilley :
does not
2026-09-02 18:07:09
1
J.R.Adams :
And then what if you have a wild leg or a Delta? which some places have for extra voltage to start motors
2026-09-02 23:56:04
1
fastpitchDADof4 :
230volt wye is not that I have heard . Very common
2026-09-03 00:00:43
1
Luciano Crisóstomo :
The most electric motors are design 208/240 volts
2026-09-04 12:55:39
0
agnesodvzbb :
stella! oppure triangolo a 380
2026-09-04 16:12:37
0
andreasschmidt124 :
it's within tolerance
2026-09-03 21:47:38
0
71Montess :
WYE. Y
2026-09-03 17:45:11
0
Apple User95734957 :
😴
2026-09-06 17:51:10
0