@mgplumbinginc: In the #plumbing field for new residential construction we have many RULES we have to follow from our Code Books. #careertipstiktokcontest Watch this #plumber explain what a Wet Vent is. #fyp @🇺🇸 BuildingCodeCollege.com did I nail it 😁
Did you know you can call the UPC or IPC and ask questions about the code. You even get real answers. I Bet you didn't know that's what your code official is doing when they are "getting back to you".
2026-09-05 03:15:35
0
jeremyjackson13 :
So you are saying if it’s done exactly the same only the let’s pretend the sink is not there. You just have the vent. Then you wouldn’t do it that way. I’m just trying to help teach you that your reasoning is a little off. I’ll ignore all the other issues and just focus on how you think it has to be a wet vent. That’s just not accurate.
2026-09-05 00:44:46
0
John cusumano :
nothing wrong with wet venting but you need to upsize the pipe 1 diameter. the sink drain should be 2inch
2026-09-02 23:40:48
3
JNashville :
IPC says you’re wrong .
2026-09-03 01:18:53
2
Antle :
Super annoying how everyone says it’s wrong or something. Remember this, we all don’t live in the same state, country. We all have different codes lol
2026-09-03 19:18:02
1
Bill Donohu :
your wet vent has to be 2"
2026-09-05 00:22:50
1
Littlebit 120 :
Flat vent. Bs. That’s not a wet vent here
2026-09-03 01:02:00
1
user3886405495194 :
Needs to be one pipe size bigger
2026-09-03 18:10:19
1
Joseph Healey :
That's illegal in ny. You can run a vent horizonalty only if it's a wet vent and has to be 2".
2026-09-03 16:06:57
1
Chris :
They make us use 2” but yeah looks kosher to me nice
2026-09-02 22:15:13
3
🇧🇲 J.MILLS 🇧🇲 :
whats the longest distance your vent needs to be to your fixture where your from ?
2026-09-03 23:36:46
1
fixxer :
What state can you wet vent with inch and a half?
2026-09-03 17:44:55
1
Soundsforever :
The trap is over 5’-0”
2026-09-04 00:31:39
0
Pipemstr :
In MN we’d need a 2” pipe, 3” if underground. Question for you though; could you grab the tub before the lav?
2026-09-03 02:31:10
1
John Pestillo :
You are kind of right about where the holes are drilled, but I would say that the waist and venting of that inch and half pipe is predicated on the amount of fixture units that the pipe can carry and the volume of air that should be sufficient for a wet vent if it’s only carrying the lab and the shower
2026-09-02 22:35:49
1
Michael :
But you’re not drilling in the center third of the joist…
2026-09-02 22:05:33
1
68Charger :
A symmetrical ( Y )connection of the tub would of corrected all those bends at the Lavatory and still be wet vented British Columbia Code 👍
2026-09-03 16:22:43
1
Reggie decker :
In our jurisdiction that is not allowed
2026-09-03 04:11:30
0
jski9713 :
You are the only guy on here truly explaining what you're doing, why and explaining code in an easy everyday way to follow. Thank you.
2026-09-02 21:14:13
3
brandonredler0 :
My state makes me 2” but the arm for the sink can be 1-1/2”😪😅
2026-09-03 00:27:42
1
KO MADMAX :
Depends on how far away that 2 inch trap is from your vent
2026-09-02 20:39:24
1
driveby_128 :
That is totally 100% wrong to make that vent both fixtures. You would have to come to the back of the wide with the sink and continue on with the bathtub hence venting 3 fixtures.
2026-09-02 17:41:41
2
Allen :
Great job!
2026-09-03 01:48:09
1
Mr Mcmurphy :
Can’t use 1 1/2 for wet vent not were I’m located anyway
2026-09-02 17:35:31
1
deadheart1978 :
I would’ve done a 2 inch drain for wet venting
2026-09-02 15:11:51
1