@todayinjakarta: #jakarta #jakartaselatan #citylights #dkijakarta #jakartahits

todayinjakarta
todayinjakarta
Open In TikTok:
Region: ID
Friday 04 September 2026 14:41:01 GMT
9559
438
2
40

Music

Download

Comments

lily_.344
lily :
Budara HI ini emang bagus dan indah....lain dari pada kota-kota lain
2026-09-05 08:21:47
0
penihrahmawati
penny mariamsari :
♥️♥️♥️♥️♥️♥️♥️🇲🇨🇲🇨🇲🇨
2026-09-24 15:08:58
0
To see more videos from user @todayinjakarta, please go to the Tikwm homepage.

Other Videos

Understanding Variable Frequency Drive (VFD) connections is essential for reliable motor control and automation troubleshooting. This schematic illustrates a complete setup for a Delta VFD-EL controlling a 3-phase AC induction motor. Key Wiring Breakdown  * Main Power Supply Input: 380V 3-Phase power feeds into the top main line terminals (R, S, T) through a circuit breaker (-QF) for overcurrent protection.  * Motor Output Power: Terminals U, V, W connect directly to the 3-phase electric motor terminals.  * Frequency / Speed Reference: A 3-terminal Potentiometer is connected to 10V (Power supply), AVI (Analog Voltage Input 0–10V), and GND (Ground) to adjust motor RPM manually.  * Digital Inputs (Control Switches):    * Forward Pushbutton: Connected between M0 (Multi-Function Input 1) and GND.    * Reverse Pushbutton: Connected between M1 (Multi-Function Input 2) and GND.    * Stop Pushbutton: Connected between M2 (Multi-Function Input 3) and GND.  * Dynamic Braking: A Braking Resistor connects to terminals B1 and B2 to dissipate regenerative energy during quick deceleration or stopping.  * Status & Alarm Indication: Multi-function relay output terminals (RA, RB, RC) power a Warning Light Tower to display drive operational status or fault conditions. Pro Tips for Installation  * Always separate low-voltage control signals (potentiometer/pushbuttons) from high-power line cables to prevent electromagnetic interference (EMI).  * Ensure proper grounding for both the drive enclosure and the motor chassis to maintain safe operation.  * Double-check parameter configurations (such as source of frequency and operation commands) to match external wiring logic before powering up. #Automation #ElectricalEngineering #VFD #DeltaVFD #MotorControl
Understanding Variable Frequency Drive (VFD) connections is essential for reliable motor control and automation troubleshooting. This schematic illustrates a complete setup for a Delta VFD-EL controlling a 3-phase AC induction motor. Key Wiring Breakdown * Main Power Supply Input: 380V 3-Phase power feeds into the top main line terminals (R, S, T) through a circuit breaker (-QF) for overcurrent protection. * Motor Output Power: Terminals U, V, W connect directly to the 3-phase electric motor terminals. * Frequency / Speed Reference: A 3-terminal Potentiometer is connected to 10V (Power supply), AVI (Analog Voltage Input 0–10V), and GND (Ground) to adjust motor RPM manually. * Digital Inputs (Control Switches): * Forward Pushbutton: Connected between M0 (Multi-Function Input 1) and GND. * Reverse Pushbutton: Connected between M1 (Multi-Function Input 2) and GND. * Stop Pushbutton: Connected between M2 (Multi-Function Input 3) and GND. * Dynamic Braking: A Braking Resistor connects to terminals B1 and B2 to dissipate regenerative energy during quick deceleration or stopping. * Status & Alarm Indication: Multi-function relay output terminals (RA, RB, RC) power a Warning Light Tower to display drive operational status or fault conditions. Pro Tips for Installation * Always separate low-voltage control signals (potentiometer/pushbuttons) from high-power line cables to prevent electromagnetic interference (EMI). * Ensure proper grounding for both the drive enclosure and the motor chassis to maintain safe operation. * Double-check parameter configurations (such as source of frequency and operation commands) to match external wiring logic before powering up. #Automation #ElectricalEngineering #VFD #DeltaVFD #MotorControl

About