@thehvacgame: I used to be scared of service calls that had these motors 😱 This is for you if you are uncertain about how to troubleshoot and diagnose ECM motors. When I first started out in air conditioning ECM motors were so scary. I had no idea how to troubleshoot or diagnose them and I did not understand any of the wires going in or out of them. Needless to say, I had to learn and overcome my own fear, but it did take a while to fully understand how they worked. Let’s break it down to hopefully make it a little bit easier for you. The two basic things you will have to verify is, if your line voltage is present to the motor, and if your control voltage is present as well. Check the unit data tag, or the motor data tag to find out what the line voltage is supposed to be. Also verify what your control voltage is supposed to be. Depending on unit and make, some of them operate on 24 VAC and some of them operate on 0 to 10 VDC. If you have any questions, always refer to your equipment manual. Once you have confirmed that your line voltage is present move onto your control voltage. The benefit of an ECM motor is that it has different speeds for different modes, such as single stage cooling, two stage cooling, or heating mode and therefore consumes less energy. Ensure you find the common wire (for control voltage) and then test to the terminal for whichever stage you’re in. If it’s low speed for single stage cooling, test to that. If it’s high speed for second stage cooling, obviously test to that. If high voltage and control voltage are present, but your motor is not operating, it is very likely that your ECM motor has failed and needs to be replaced. Obviously also check for damaged wires or the motor being seized up mechanically and not turning at all. Hope this helped. If you’re tired of second-guessing your own diagnostic, you want to master troubleshooting and accelerate your career, join the HVAC Game Skool community. I’d love to see you there. Happy HVACing 🤙 #hvac #hvacservicetech #hvacapprentice #hvactroubleshooting #creatorsearchinsights
The HVAC game
Region: US
Wednesday 09 September 2026 23:15:24 GMT
Music
Download
Comments
Devon :
Check the plug?
2026-09-24 02:11:47
0
q.sc707_ :
So let’s say u had the 120 for ur line voltage but you didn’t have the call for ur low voltage going to it is that a board issue then bad board ? Came across calls like that knowing motor is still good
2026-09-10 23:42:52
0
James m :
or pick up a variable speed zebra! Worth the money
2026-09-10 01:27:15
11
taylorrrrr :
I don’t know much about blowers yet they’ve been tripping me up on calls. Can you not just unplug the wires from the motor and test for high voltage and low going to the motor directly at the harness. And condemn the motor if voltage is present?
2026-09-10 03:29:58
4
SUPERPAN :
expensive motors?
2026-09-10 00:39:07
3
Connor :
For Trane and American standard 👍🏼
2026-09-10 23:17:07
5
Prime Frost HVAC :
Nice approach. Thank you very much!
2026-09-12 00:22:00
1
bringler85 :
Sc680 meter helps with this doesn’t it?
2026-09-10 19:18:38
0
Pluto :
You don’t have to do all that to check the blower
2026-09-10 16:31:46
1
tamagoeggs :
It’s as simple as checking where you have power and don’t guys
2026-09-11 04:10:14
0
Surujnarine Pundit :
thank u sir
2026-09-10 03:09:51
0
غريب :
coo
2026-09-10 03:52:36
0
juangarza3077 :
👍👍
2026-09-10 01:56:50
0
One ☝🏿 J BREEZY (Jimhejah) :
School
2026-09-10 07:01:16
0
Carlos Jimenez :
Thx
2026-09-09 23:25:29
0
tutymas2 :
Those carrier ones are the easiest because they have the tabs for the low voltage right there on the board. I has the Common/ Heat/ Cool/ Fan and 2 park speeds. I had one last week and it was giving me 7 volts between the cool and common tabs at the board so they are really easy to diagnose for the new guys
2026-09-10 01:45:23
0
KeepWatching50q :
Bad motor
2026-09-11 12:15:55
0
imad dannun :
👍👍👍
2026-09-10 22:47:24
0
coolservice06 :
👏👏👏
2026-09-10 01:43:19
0
8321Cizzle :
💯💯💯
2026-09-23 04:33:58
0