@hendythesparky: Master Electrician Dad Quizzes Apprentice Son on Hospital Electric, and Hospital Grade Red Emergency Outlets, Thoughts? @Henelect #electrician #bluecollar #electricalcontractor #hendythesparky #trending

Hendy The Sparky
Hendy The Sparky
Open In TikTok:
Region: US
Thursday 24 September 2026 06:30:53 GMT
46005
2500
25
70

Music

Download

Comments

justinfoster43
CategoricToast :
False, none of the shown receptacles may be used. All receptacles within the waiting room shall be Tamper-Resistant type
2026-09-26 01:37:41
0
de_trezz14
Dario J Detres Figue :
dosent the green dot mean isolated to ground?
2026-09-24 11:04:55
15
jonny_jon_jon_13
jonny_jon_jon_13 :
The Green dot means it has an isolated ground which means it's separate from the wire that is grounding the physical device box
2026-09-24 13:43:52
5
kaywiredthat
kaywiredthat :
W knowledge
2026-09-25 13:57:02
0
trashmain.exe
trashman.exe🇨🇦 :
green is the designated colour of oxygen tanks. could be part of the reason there is a green sticker. in canada some of our hospital outlets simply have an orange triangle, i cant remember exact but i think my jman said it was because it needs a dedicated ground so as to avoid shocking patients/surges for equipment if fault current is present. but idk. im only first year trying to learn.
2026-09-24 11:46:56
0
cube3x3
ㅤ :
Red just means the plug is backed by a generator or an ups
2026-09-24 21:55:18
2
mattman782
Matt :
I saw this being filmed on the live last night!! I learned some great stuff from you guys, thank you for your videos
2026-09-24 11:13:03
0
dino20091
Bernie R :
Red outlet emergency
2026-09-24 23:52:45
1
lawrencef101
lawrence101 :
NEC 517.16
2026-09-24 14:14:39
2
alexrivera713
Alex Rivera :
At MDA in Houston we only use Hospital Grade Receptacles. Non is never allowed
2026-09-25 02:33:47
0
sparkey862
sparky :
It also should have a isolated ground other the the equipment ground
2026-09-24 23:33:19
1
majority6658
TC :
I got a question - what outlets need yearly testing? Answer that one? 😁
2026-09-25 02:20:22
0
erikkelly471
EKell471 :
Right on guys and thanks for showing Pass & Seymour devices. If you need samples let me know.
2026-09-24 17:20:44
0
tmg.cameron
Tmg.cameron :
Good stuff good stuff
2026-09-25 02:04:20
0
3lyxz5
3lyxz :
A lot of this in the video is also the reason why emergency lighting has 12-3 wire, not a lot of apprentices, realize that
2026-09-25 02:14:58
0
usergevth46ktn
RunOffWitKidz4GovHelp304’s :
The most expensive 🔌
2026-09-24 13:05:33
0
angelsolache0
Angel Solache :
I would have never guessed that one genius
2026-09-24 23:15:56
0
To see more videos from user @hendythesparky, please go to the Tikwm homepage.

Other Videos


About