@amani.ishaq67:

🌺🌹Amani 🌹🌺Ishaq🌺
🌺🌹Amani 🌹🌺Ishaq🌺
Open In TikTok:
Region: NG
Tuesday 06 October 2026 16:51:22 GMT
32771
2450
23
95

Music

Download

Comments

maxwellozodigwe
Maxwell 002 :
Beautiful
2026-10-07 14:22:40
0
sadeqsadeq9802
SADEQ SADEQ :
Rufaida yoghurt wholesale and retail store
2026-10-07 15:36:22
0
user6130615559473
MALAM JEGA :
ykklfy ♥️♥️🌹
2026-10-07 11:25:09
0
daudayamta1
daudayamta669 :
yes my baby
2026-10-07 17:21:59
0
umar_gk8
@Umar_gk8 :
gk
2026-10-07 14:24:44
0
abdulaziz.manci
Abdulaziz Manci :
kaya iya kaya
2026-10-07 12:05:04
0
yusuf.amana16
Yusuf amana :
Kwana nawa
2026-10-07 13:29:30
0
s_dankaka
S.Dankaka :
Nono
2026-10-07 08:29:53
0
ibrahim.jibrin.ra
Ibrahim jibrin Rabiu :
inaso muhadu
2026-10-07 11:12:26
0
ibb37560
ibb :
hi
2026-10-07 06:12:00
0
ayuba.salisu.imam
Ayuba Salisu Imam :
wai wai wai tab
2026-10-07 09:34:42
0
haji.done7
Haji Done :
2026-10-07 17:20:53
0
user5639586570595
MUHAMMAD nabiyu :
2026-10-07 10:38:16
0
mohammedharuna5663
mohammedharuna5663 :
ky
2026-10-07 11:35:14
0
adomusa006gmail.com
Pullo :
Tarbiya
2026-10-07 08:03:52
0
aliyuyahaya8139
Aliyu Yahaya85 :
😁😁😁
2026-10-07 16:39:21
0
niang116002663
boyi niang :
❤️❤️❤️
2026-10-07 01:26:27
0
user75362297945832
Usman :
😂😂😂
2026-10-07 10:55:05
0
sanifaya227
manman Sani :
😇😇😇😇😇😇
2026-10-07 12:32:47
0
mamidou.abdoullah
Mamidou abdoullahi Dogo :
🥰🥰🥰
2026-10-07 09:16:57
0
jakanamusa
jaka :
🥰🥰🥰
2026-10-07 09:16:31
0
tijani.issoufou227
Tijani issoufou227 :
🥰🥰🥰
2026-10-07 14:05:48
0
43477888uy6uu7u6655r
92 :
🥰🥰🥰
2026-10-07 17:10:44
0
abdullahihudu690
Abdullahi HuDu :
🥰🥰🥰
2026-10-07 18:16:28
0
To see more videos from user @amani.ishaq67, please go to the Tikwm homepage.

Other Videos

ဆိုလာစနစ်တွေမှာ အင်ဗာတာ မပျက်စီးအောင်နဲ့ မီးလောင်ကျွမ်းမှု လုံးဝမဖြစ်စေဖို့ DC Combiner Box ကို စိတ်ကြိုက်တပ်လို့ မရပါဘူး။ နိုင်ငံတကာ IEC စံချိန်စံညွှန်းတွေအရ ကာကွယ်ရေး Zone (၃) ခု တိတိကျကျ ခွဲခြားတပ်ဆင်ရပါတယ်ခင်ဗျာ။ ​စံချိန်စံညွှန်းပြည့် ချိတ်ဆက်မှု အစဉ်လိုက်: PV Strings ➡️ 4P 32A Isolator ➡️ [DC SPD // 2P 25A MCB] ➡️ 25A gPV Fuses ➡️ Inverter ​Zone 1: Primary Load-Break Isolation (IEC 60947-3 / DC-PV2) အမိုးပေါ်က မီးအရှင်ကို အင်ဗာတာ လည်ပတ်နေချိန်မှာတောင် Full-load အခြေအနေမှာ ဘေးကင်းစွာ ဖြတ်တောက်ပြီး ပြုပြင်ထိန်းသိမ်းသူတွေ ဓာတ်မလိုက်အောင် Zero-Energy State အပြည့်အဝ ဖန်တီးပေးပါတယ်။ ​Zone 2: Surge Clamping & Overcurrent Protection (IEC 61643-31 // IEC 60947-2 Annex P)  ​Type 2 DC SPD: MCB ရဲ့ အပေါ်ဘက် Line-side မှာ Parallel ဆွဲထားရပါမယ်။ MCB ခလုတ်ကျသွားရင်တောင် မိုးကြိုးလွှဲစနစ် မပြတ်တောက်ဘဲ မြေကြီးထဲ စဉ်ဆက်မပြတ် လွှဲချနိုင်အောင် ဖြစ်ပါတယ်။ (လိုင်းကြိုး + PE ကြိုး စုစုပေါင်းအလျား 50 cm အောက်သာ ထားရမည့် 0.5m Rule ကို လိုက်နာပါ)။ ​2P 25A DC MCB: 590W Bifacial ပြားတွေရဲ့ အလင်းပြန်အား Continuous Current (17.5A) နဲ့ ဘူးအတွင်းပိုင်း 50°C ကျော် အပူချိန်ဒဏ်ကြောင့် ခလုတ်အလဟဿ မကျသွားအောင် 25A သတ်မှတ်ချက်ကို တိကျစွာ ရွေးချယ်ထားပါတယ်။ ​Zone 3: Supplementary Backfeed Isolation (IEC 60269-6 / UL 248-19) Inverter DC အဝင်ဝ မရောက်မီ ကပ်လျက်မှာ တပ်ဆင်ရပါမယ်။ Inverter bus capacitor တွေဆီကနေ လျှပ်စီးတွေ နောက်ပြန်ကန်ထွက်လာမည့် Reverse Backfeed Current တွေကို အမြန်ဆုံး ဖြတ်တောက်ပေးပြီး ဘူးနဲ့ ဆိုလာပြားတွေ မီးလောင်ကျွမ်းမှု မဖြစ်အောင် တားဆီးပေးတဲ့ နောက်ဆုံးခံတပ် ဖြစ်ပါတယ်။ ​Cabling & Earthing Rules: အတွင်းကြိုးလိုင်းအားလုံးကို 6 mm² XLPO Solar Cable (IEC 62930) သုံးပြီး SPD မြေစိုက်ကြိုးကို အနည်းဆုံး 10 mm² Cu၊ မြေစိုက် Ground Rod ဆင်းကြိုးကို 10 mm² Cu ဖြင့် စနစ်တကျ မြေစိုက်ချိတ်ဆက်ပေးရပါမယ် (Earth Resistance 10 Ohm အောက်)။ ​စံချိန်စံညွှန်းပြည့်မီပြီး ဘေးကင်းစိတ်ချရတဲ့ ဆိုလာစနစ်ဖြစ်ဖို့ ဗီဒီယိုကို အခုပဲ Save လုပ်ထားပြီး အသိပညာမျှဝေလိုက်ပါခင်ဗျာ! ☀️⚡ random component placement inside your DC combiner box creates severe fire and equipment hazards. To ensure maximum reliability and full compliance with international standards, you must divide your DC protection into 3 dedicated zones under IEC 60364-7-712. Standard Wiring Topology (Path A Sequence): PV Strings ➡️ 4P 32A Isolator ➡️ [DC SPD // 2P 25A MCB] ➡️ 25A gPV Fuses ➡️ Inverter Zone 1: Primary Load-Break Isolation (IEC 60947-3 / DC-PV2) A true 4-In / 4-Out 1000V switch-disconnector provides safe manual load-break capability under full operating current, establishing a verified zero-energy state for service personnel to work without electric shock risk. Zone 2: Surge Clamping & Overcurrent Protection (IEC 61643-31 // IEC 60947-2 Annex P) Type 2 DC SPD: Parallel-tapped directly on the line side (upstream) of the MCB. This guarantees uninterrupted lightning surge diversion to ground even if the breaker trips. Keep total lead length strictly under 50 cm (the 0.5m rule) to prevent inductive voltage spikes. 2P 25A DC MCB: Sized at 25A to clear the bifacial continuous design current (21.9A) while factoring in thermal derating inside 50°C+ sealed outdoor enclosures. Zone 3: Supplementary Backfeed Isolation (IEC 60269-6 / UL 248-19) Positioned immediately ahead of the inverter DC inputs. These 25A gPV fuses act as the final defense line, interrupting high-energy reverse backfeed currents discharged from inverter DC-link capacitors during internal faults. Conductor & Earthing Specifications: Route all DC power paths using 6 mm² XLPO double-insulated solar cable (IEC 62930). Bond SPD ground terminals using dedicated 10 mm² copper leads, and connect the combiner earth bar to the main earth rod using a continuous 10 mm² copper conductor (Earth Resistance 10 Ohms or less). Build your solar systems with engineering precision rather than guesswork. Save this video for your next installation and share it with your team! ☀️⚡ #SolarInstallation #DCDistributionBox #ElectricalSafety #KnowledgeSharing #NewApproach
ဆိုလာစနစ်တွေမှာ အင်ဗာတာ မပျက်စီးအောင်နဲ့ မီးလောင်ကျွမ်းမှု လုံးဝမဖြစ်စေဖို့ DC Combiner Box ကို စိတ်ကြိုက်တပ်လို့ မရပါဘူး။ နိုင်ငံတကာ IEC စံချိန်စံညွှန်းတွေအရ ကာကွယ်ရေး Zone (၃) ခု တိတိကျကျ ခွဲခြားတပ်ဆင်ရပါတယ်ခင်ဗျာ။ ​စံချိန်စံညွှန်းပြည့် ချိတ်ဆက်မှု အစဉ်လိုက်: PV Strings ➡️ 4P 32A Isolator ➡️ [DC SPD // 2P 25A MCB] ➡️ 25A gPV Fuses ➡️ Inverter ​Zone 1: Primary Load-Break Isolation (IEC 60947-3 / DC-PV2) အမိုးပေါ်က မီးအရှင်ကို အင်ဗာတာ လည်ပတ်နေချိန်မှာတောင် Full-load အခြေအနေမှာ ဘေးကင်းစွာ ဖြတ်တောက်ပြီး ပြုပြင်ထိန်းသိမ်းသူတွေ ဓာတ်မလိုက်အောင် Zero-Energy State အပြည့်အဝ ဖန်တီးပေးပါတယ်။ ​Zone 2: Surge Clamping & Overcurrent Protection (IEC 61643-31 // IEC 60947-2 Annex P) ​Type 2 DC SPD: MCB ရဲ့ အပေါ်ဘက် Line-side မှာ Parallel ဆွဲထားရပါမယ်။ MCB ခလုတ်ကျသွားရင်တောင် မိုးကြိုးလွှဲစနစ် မပြတ်တောက်ဘဲ မြေကြီးထဲ စဉ်ဆက်မပြတ် လွှဲချနိုင်အောင် ဖြစ်ပါတယ်။ (လိုင်းကြိုး + PE ကြိုး စုစုပေါင်းအလျား 50 cm အောက်သာ ထားရမည့် 0.5m Rule ကို လိုက်နာပါ)။ ​2P 25A DC MCB: 590W Bifacial ပြားတွေရဲ့ အလင်းပြန်အား Continuous Current (17.5A) နဲ့ ဘူးအတွင်းပိုင်း 50°C ကျော် အပူချိန်ဒဏ်ကြောင့် ခလုတ်အလဟဿ မကျသွားအောင် 25A သတ်မှတ်ချက်ကို တိကျစွာ ရွေးချယ်ထားပါတယ်။ ​Zone 3: Supplementary Backfeed Isolation (IEC 60269-6 / UL 248-19) Inverter DC အဝင်ဝ မရောက်မီ ကပ်လျက်မှာ တပ်ဆင်ရပါမယ်။ Inverter bus capacitor တွေဆီကနေ လျှပ်စီးတွေ နောက်ပြန်ကန်ထွက်လာမည့် Reverse Backfeed Current တွေကို အမြန်ဆုံး ဖြတ်တောက်ပေးပြီး ဘူးနဲ့ ဆိုလာပြားတွေ မီးလောင်ကျွမ်းမှု မဖြစ်အောင် တားဆီးပေးတဲ့ နောက်ဆုံးခံတပ် ဖြစ်ပါတယ်။ ​Cabling & Earthing Rules: အတွင်းကြိုးလိုင်းအားလုံးကို 6 mm² XLPO Solar Cable (IEC 62930) သုံးပြီး SPD မြေစိုက်ကြိုးကို အနည်းဆုံး 10 mm² Cu၊ မြေစိုက် Ground Rod ဆင်းကြိုးကို 10 mm² Cu ဖြင့် စနစ်တကျ မြေစိုက်ချိတ်ဆက်ပေးရပါမယ် (Earth Resistance 10 Ohm အောက်)။ ​စံချိန်စံညွှန်းပြည့်မီပြီး ဘေးကင်းစိတ်ချရတဲ့ ဆိုလာစနစ်ဖြစ်ဖို့ ဗီဒီယိုကို အခုပဲ Save လုပ်ထားပြီး အသိပညာမျှဝေလိုက်ပါခင်ဗျာ! ☀️⚡ random component placement inside your DC combiner box creates severe fire and equipment hazards. To ensure maximum reliability and full compliance with international standards, you must divide your DC protection into 3 dedicated zones under IEC 60364-7-712. Standard Wiring Topology (Path A Sequence): PV Strings ➡️ 4P 32A Isolator ➡️ [DC SPD // 2P 25A MCB] ➡️ 25A gPV Fuses ➡️ Inverter Zone 1: Primary Load-Break Isolation (IEC 60947-3 / DC-PV2) A true 4-In / 4-Out 1000V switch-disconnector provides safe manual load-break capability under full operating current, establishing a verified zero-energy state for service personnel to work without electric shock risk. Zone 2: Surge Clamping & Overcurrent Protection (IEC 61643-31 // IEC 60947-2 Annex P) Type 2 DC SPD: Parallel-tapped directly on the line side (upstream) of the MCB. This guarantees uninterrupted lightning surge diversion to ground even if the breaker trips. Keep total lead length strictly under 50 cm (the 0.5m rule) to prevent inductive voltage spikes. 2P 25A DC MCB: Sized at 25A to clear the bifacial continuous design current (21.9A) while factoring in thermal derating inside 50°C+ sealed outdoor enclosures. Zone 3: Supplementary Backfeed Isolation (IEC 60269-6 / UL 248-19) Positioned immediately ahead of the inverter DC inputs. These 25A gPV fuses act as the final defense line, interrupting high-energy reverse backfeed currents discharged from inverter DC-link capacitors during internal faults. Conductor & Earthing Specifications: Route all DC power paths using 6 mm² XLPO double-insulated solar cable (IEC 62930). Bond SPD ground terminals using dedicated 10 mm² copper leads, and connect the combiner earth bar to the main earth rod using a continuous 10 mm² copper conductor (Earth Resistance 10 Ohms or less). Build your solar systems with engineering precision rather than guesswork. Save this video for your next installation and share it with your team! ☀️⚡ #SolarInstallation #DCDistributionBox #ElectricalSafety #KnowledgeSharing #NewApproach

About