@sandovalelectricllc: SANDOVAL ELECTRIC ⚡️ The breaker is OFF… but are you ready to start working? 🤔🔧 Before you pick up that screwdriver, take a look at the choices. What would YOU do next? 🅰️ Yes, start working. 🅱️ Verify absence of voltage. 🅲 Only if the lights are off. 👇 Comment A, B, or C—and explain WHY. Experienced electricians: what safety lesson do you wish someone had taught you on your first day? Our goal is to help people starting in this trade ask questions, build knowledge, and learn from experienced professionals. Keep the discussion respectful—someone reading your comment could learn something valuable. Follow for more electrical tips and challenges! 👊⚡️ Educational discussion—not a complete electrical safety procedure. #SandovalElectric #Electrician #ElectricalSafety #ElectricianApprentice #ElectricalTips

sandovalelectricllc
sandovalelectricllc
Open In TikTok:
Region: US
Wednesday 07 October 2026 21:07:10 GMT
2822
27
21
1

Music

Download

Comments

5.7_blueobs
5.7_blueobs :
treat every wire as if its hot. like how you treat a gun as if its loaded even if you know its not. If you treat every wire this way and test voltage and verify power is dead you are much less likely to get electrocuted
2026-10-07 23:18:02
1
jay238925
jay :
B should work [Smile]
2026-10-10 00:07:11
2
ironhyde09
ironhyde09 :
b is a must never trust a breaker
2026-10-08 01:17:03
2
mchieffalo
Mike Chieffalo :
Use lockout tag out next. Then test wiring to make sure it’s dead.
2026-10-11 17:27:43
0
turnkey497
Turnkey497 :
B. Because electricity back feeds under certain circumstances and breakers are mechanical devices that may be defective. Always check you meter on a known live source to ensure it’s working correctly. Then test your open circuit. Then check meter again on a live circuit just to be sure the meter is still working properly. Now you can be satisfied the circuit you’re working on is open.
2026-10-10 06:33:54
2
babymule63
babymule63 :
B..and then do a lock out and tag..
2026-10-19 13:15:29
0
dlp196812
dlp196812 :
B and also use a breaker lock out.
2026-10-08 22:42:26
0
johnclark3346
johnclark3346 :
B always use a tester
2026-10-13 22:38:56
0
tictok.comlog5
Jim :
no lock out tag on there
2026-10-10 18:25:00
0
jr11891
jr :
B check with a meter for o voltage
2026-10-15 00:30:17
0
luis.rubio777
Luis Rubio :
B
2026-10-09 22:19:54
1
rcb7409
RCB :
B
2026-10-08 01:59:28
1
darin.aschbrenner
Darin Aschbrenner :
treat it live or ground it dead
2026-10-08 00:29:03
1
lostinspace1998
Lost in space :
B
2026-10-07 22:33:02
1
andygarcia611
Andy Garcia :
B
2026-10-08 22:52:26
0
dangrouch1
Dangrouch1 :
B
2026-10-08 23:03:28
0
spud7345
Spud :
😳😳😳
2026-10-08 22:23:30
0