@letsbetechs: ​How many of you replace belts as part of an annual preventive maintenance check? ​Over time, belts stretch and wear down. Most customers in our area wait until a belt snaps—turning a simple fix into an emergency. ​Before they fail completely, loose belts reduce airflow, which can freeze up the entire coil. As that ice expands, it does serious damage: bending copper, creating refrigerant leaks, and even cracking concrete! ​This customer is moving to an annual belt replacement schedule. Now, when I pull the old belts off next year, they’ll still be in great shape to keep on-site as emergency spares. 🔧⚙️ ​#hvac #hvacapprentice #hvactechnician #hvaclife #preventivemaintenance

Lets Be Techs
Lets Be Techs
Open In TikTok:
Region: US
Saturday 10 October 2026 14:16:20 GMT
257868
5343
137
57

Music

Download

Comments

theoriginalsoulsouljah
:John: Honewaatamokepumipi🇨🇳 :
belts on the wrong side of the tensioner
2026-10-10 18:46:57
28
protestantpilot
Steve T :
I think your belt is on the wrong side of the tensioner. The tensioner pulley looks flat, which means it should be touching the wide face of the belt.
2026-10-11 06:41:11
10
that_roddy
Roddy :
Install a tensioner, get more life out of the besllt
2026-10-10 16:16:13
113
tubs0906
tubs :
Did you tag out lock out it?
2026-10-10 21:20:52
6
darthjuju
RussianBeard :
You took out topnotch cardboard from 2nd one but not first 😅
2026-10-10 17:16:28
8
timbo.mcslice
timbo.mcslice :
Nah that’s belts fine. Unit just needs some freezon.
2026-10-10 16:01:30
69
genxvamp1
GenXvamp :
belt is the wrong size as you are over 80% of the adjustment rail
2026-10-11 09:20:29
10
electrician_welder
tnsparky :
That’s the best design ever for the tensionln pulley
2026-10-10 23:40:04
9
jacob.whittaker
Jacob W :
It's certainly not setup the way I'd expect. I'd expect the belt to be on the outside of the belt putting tension on the outside.
2026-10-10 18:41:39
5
johnlong673
J lizzle :
zip tie them comm wires
2026-10-11 14:38:26
2
phoinixbird
phoinixbird :
New belts once a year here
2026-10-10 21:07:21
3
ely_stott
Thomson Gerard Foolery :
Is the black dust looking stuff belt material?
2026-10-11 06:01:24
0
hvacmom
Jaime - HVAC Mom :
People get so worked up when it comes to belts 😂😂
2026-10-10 22:56:19
2
wintersquid
Preston Downs :
It’s only loose on the bottom. Just fix that part of it and you’re good
2026-10-13 16:07:44
1
cinek306
Cinek :
is it well mounted? seems the belt should go from outside
2026-10-19 12:17:45
0
fsk13715
fsk137 :
nice job!
2026-10-10 21:03:30
3
buddygaston1
Buddy Gaston :
You left the cardboard in the first unit.
2026-10-10 22:10:40
1
mynameisuhgg
blahblahblah.. :
Back in the day, those tensioners came in plastic. It would always fall apart and then they started making them in metal. Nice change.
2026-10-16 13:41:59
1
stevenjennings57
Steven Jennings :
🙏That belt is definitely loose 🙏
2026-10-10 20:16:02
3
dandavid24
Dan David :
Wouldn't it ha e worked better to move that tensioner in to position without the belt on, and then force the belt on by turning the fan pulley just like you did when it was slightly off just now ?
2026-10-10 17:10:30
1
mickmick01
Mickel :
why not use a V belt instead of a toothed belt?
2026-10-10 23:23:53
1
seriousvik
Viktor :
you got the new belt all bound-up on the big pulley 😁
2026-10-10 19:35:45
4
doneldridge831
doneldridge831 :
Did you lube pillow blocks or motors?
2026-10-10 17:51:44
0
joelmolaison
Joel Molaison :
put a pulley like this...greater contact surface area with the fan and the engine pulley
2026-10-11 04:17:24
4
john.vincent980
John Vincent :
that’s not how you test belt tension You’re just pissing in the wind there. The realway to test belt tension is with a belt touching gauge.
2026-10-10 17:00:07