@hendythesparky: POV: An Electrician Installing a Home EV Charger for $2,790.00, 125 FT Wire Run; What an Entire Job looks like Start to Finish, Thoughts? #electrician #bluecollar #electricalcontractor #hendythesparky #trending

Hendy The Sparky
Hendy The Sparky
Open In TikTok:
Region: US
Tuesday 20 October 2026 22:55:01 GMT
43824
1935
117
88

Music

Download

Comments

sparkyyyyy762
Brandon ⚡️ :
$2800????? Jesus
2026-10-21 02:16:06
20
caseysmithracing
Casey Smith :
what’s the point of offset??? just continue the 90🤨
2026-10-21 00:18:06
168
xi.xximmiv
xxi :
POV Tesla hard wired is rated for 48 amps of continuous load, therefore you have to size it at 125% which would be 60amps continuous load. 6/2 nmb is setting your customer up for failure. No max performance
2026-10-21 05:25:01
10
smkelectrical
smkelectrical :
My local inspector wants us running copper 6/2 SEU or MC for a car charger because you need to multiply your 48a EV at 125%. 6/2 NM isn’t rated for 60a.
2026-10-21 19:48:12
0
bcunningham2021
bcunningham2021 :
im just here for all the comments
2026-10-21 00:11:56
23
prodpsilo
prodpsilo :
What was the point of the offset above the charger? Just curious as to why the offset was needed
2026-10-21 00:12:34
8
srt_392_pyro
SRT_Solis_392 :
Straight rat work… straps every 3 feet are you serious?
2026-10-22 20:33:52
4
shadow41300
Shadow :
Does that price include the actual charger unit?
2026-10-21 11:20:22
1
king.roy305
king roy :
GFCI breaker.
2026-10-21 01:37:40
2
yultzy
Drew :
Why not run 4AWG so if they upgrade their charger to the level 2, they’re set
2026-10-21 00:12:17
12
iggman51
Iggman51 :
Rip off no doubt.
2026-10-21 01:45:16
1
andre13714
Andre :
That length is over 50ft the wire size is under size for that continuous load ! Cannot get max output from charger. Yuh raw deal that customer
2026-10-21 09:54:53
4
pengoasteroid
PengoAsteroid :
Should have ran 6/2 MC cable all the way from panel to charger. Cheaper faster better amperage up to 60 amps.
2026-10-22 09:52:56
3
kayden_bunten
Kayden_bunten :
That charger pulls 48 amps. Unless you had the client set the amperage of the charger lower I don’t think 6 awg nmb is rated for the 48 amp continuous load
2026-10-21 04:03:16
3
bobbyf628
bobbyf628 :
we normally put those on GFI breakers
2026-10-21 02:40:27
0
jacobledesma960
Jacob :
Holy strapping
2026-10-22 03:02:01
7
craig.mca.haskins
Craig MCA Haskins :
As an electrician I can honestly say that price is criminal...!!!
2026-10-21 15:57:02
5
jrspeedy8
Puertombian :
I ran my own and all the conduit is hidden , no ceiling conduit showing , electricians take the easy way out and install 100ft of conduit all over the ceiling
2026-10-21 02:53:44
0
pengoasteroid
PengoAsteroid :
Where’s your means of disconnect?
2026-10-22 09:53:50
0
christophershay18
Christopher Shay :
Electric chargers need to be in a raceway
2026-10-21 03:17:26
1
hazzmatt_300
Hazzmatt__400 :
60 amps
2026-10-21 04:00:23
1
misaelramirez766
misaelramirez766 :
2026-10-23 00:08:19
1
kylewarren39
Kyle Warren :
I was going to say something about overcharging until I saw how long that basement was. bro could have definitely replaced that piece of conduit though and not had that offset after that 90 that just makes it ugly in the customer's garage my man
2026-10-21 01:41:25
3
steeler_in_leafs_land
Steeler_In_Leafs_Land :
As an ‘electrician’ with 5 years experience - does that mean you been licensed for 5 years OR that you are a 5th year apprentice ?
2026-10-22 02:39:55
1
s1564f
Kgt :
Volt drop enters the chat 😂
2026-10-21 01:07:24
2