please take that silicone off and replace it with self leveling lap sealant
2026-10-29 05:39:13
59
user2491404208471 Rene’e :
Women power
2026-11-27 18:40:36
0
Kevin :
NP-1 is far superior calk to silicon. NP-1 is used on commercial window fronts. It will outcast silicon 25x- 50x longer. Silicon is garbage.
2026-11-04 16:56:05
0
jarrod250 :
No service loops?
2026-11-12 20:38:02
2
Mark Littlejohn :
those wires are not supposed to be nailed together.
2026-11-15 03:32:51
5
Jason :
Best lap sealant: thervroofman.com
@itsRon
2026-11-05 23:34:13
1
Matt :
Looks really heavy
2026-10-29 05:33:14
2
Max :
Looks good!
2026-10-29 02:55:07
0
Mikey_P19 :
Have service loops and you have to de-rate the conductor ampacity if you’re going to bundle them like that
2026-11-15 19:35:33
2
TrevorViking76 :
Doing a great job bro 👍
2026-11-02 12:07:32
2
James M :
Fixed but not done correctly
2026-11-24 14:56:17
0
Reymond Jeffrey :
It’s actually better to not overlay wires so they are touching. It is better to run them side to side with the plastic separators. Plus each wire needs its own hole through studs with a few inches of separation. It’s safer.
2026-10-29 03:57:46
11
Mike H :
The wires were fine as is. The way you redid them is definitely not code compliant.
2026-11-01 14:49:51
3
Suz Gawith :
💙💙💙
2026-11-06 18:22:11
0
Christian Decena :
Your hands messed up, not your feet lol. jk just 🤣🤣🤣
2026-10-29 11:44:06
0
Gerald :
👍👍👍
2026-10-29 17:41:27
0
Timedheartache :
👍👍👍
2026-10-29 14:34:44
0
Cesar Gutierrez :
👍👍👍
2026-10-29 17:10:01
0
Voyeur :
💪
2026-11-16 04:07:26
0
Natural Discoveries Store :
Why You Shouldn't Stack or Bundle Wires
• Heat Build-up: Tightly bundling many current-carrying cables together traps heat and prevents airflow around the insulation.
• Code Derating Rules: Under the National Electrical Code (NEC), running more than three current-carrying conductors closely attached or bundled together for more than 24 inches often requires "derating" (reducing the allowable current capacity or using a larger wire size) to prevent overheating.
• Capacitive Coupling: Closely packed parallel wires can build up unwanted electrical capacitance and electromagnetic interference.
Best Practices for Running Wall Wires
• Use Cable Stackers or Individual Fasteners: In timber-framed walls, use specialized plastic cable stackers (such as Ideal-brand stackers) rather than zip-tying or bunching lines together. Stackers keep cables neatly aligned, spaced, and secured at a code-compliant distance from the drywall face.
• Run Through Bored Holes: When passing multiple non-metallic sheathed cables (Romex) through wooden studs, drill separate or adequately sized bored holes through the center of the studs rather than cramming them into a tight cluster.
• Maintain Spacing: Keep general electrical power wiring separated from low-voltage or network/data cables (aim for at least 12 inches of separation for unshielded twisted-pair data lines to avoid interference).
2026-10-29 06:06:18