Glad it's not my house. 10 inch slump concrete with no rebar. Those aren't footings. It is slightly better than flowable fill.
2026-11-12 16:09:49
74
Cooperg123 :
No concrete this is slurry fill
2026-11-12 18:40:42
3
Thomas Fitzsimmon597 :
A lot of expert engineers on here have never heard of self compacting trench flow concrere😂😂😂😂😂😂😂😂
2026-11-12 18:28:35
6
user17918186381586 :
Not a single piece of rebar in sight
2026-11-12 19:29:03
3
DAN Corbett :
no steel???
2026-11-11 23:08:59
26
sbuhris9425 :
Don’t need a laser when it’s self leveling
2026-11-12 14:41:38
112
MIKErowave :
Love wet concrete
2026-11-11 21:03:20
1
murphys125john :
Plenty of Easter Eggs in that slump 😂
2026-11-12 08:13:54
58
MARSHALL MOBIO :
Béton de propreté ??
2026-11-21 19:20:30
2
no1mixerman :
That’s a rare but welcome sight for an owner driver - so many groundworkers would use the machine bucket to do all of that even tho it’s a nice wet mix and you could probably loose the first load straight away and use the bucket to top off 👍👍
2026-11-17 23:36:56
0
Rebar King :
ALSO. NO STEEL. AND NO PIERS UNDERNEATH.
2026-11-13 02:29:26
2
Memmedov_404 :
səliqəli hazırlanıb amma bu cür beton vermək düzgün deyil 👍
2026-11-21 11:59:12
0
Kris & sons :
Wet it up drive. It’s to wet can you take some of the water out
2026-11-13 19:04:41
0
jessemendez64 :
I’d like to meet the person who dug up those trenches they are laser perfect. Look at those corners and the edges are impeccable.👍
2026-11-12 16:32:28
5
cha0s_knight :
for those who are confused on the reinforcement usage, this might helps.
In structural design, steel reinforcement is mainly used to resist tension caused by bending, as concrete is strong in compression but weak in tension.
However, not all concrete foundations require steel reinforcement. When a footing is sufficiently thick relative to its width, the load can be transferred mainly through compression, reducing bending and tensile stresses to levels that the concrete itself can safely resist. thus, the requirement of rebar in not needed.
but the soil beneath the foundation also important. It must have sufficient bearing capacity to support the load, and total and uneven settlement must remain within acceptable limits. this one subject to the soil investigation on what type of soil and the settlement allowed.
Thus, a properly designed plain concrete footing can safely support structural loads without steel reinforcement, provided that the footing dimensions, concrete grade strength, soil conditions and loading are properly assessed.
2026-11-21 18:36:25
0
GHR077 :
It'S gOT No RebAR, 3 story house were put on 100mm of crap and never moved so I think these are safe
2026-11-14 18:16:32
2
Tarik Hrvacanin :
keine Bewährung💀😭😂😂
2026-11-12 19:20:59
0
Captain🪖 :
Very solid concrete💪
2026-11-22 00:24:48
0
Andres Martinez M455 :
Exhale un poco más de agua
2026-11-12 20:35:23
6
brendujouw4 :
To a lot of comments below this is a standard house footing mix in self flow concrete. Rebar is not always needed especially in good ground which would be my assessment of this dig from what can be seen it won't be long before your onto mudstone. Nothing wrong with this job here at all 👍 Groundwork company owner and Civil Engineering 👍
2026-11-13 07:42:41
2
Dduck :
That foundation floor is butter
2026-11-12 17:17:17
3
Matthew Potestio :
Never understood why foundations aren’t reinforced
2026-11-12 15:58:13
0
Sebastien73110 :
Du s4
2026-11-12 18:45:56
0
David sinnerman :
I take it the lumps are free
2026-11-13 13:38:39
1
Nobody :
Self leveling concrete 🤦♂️
2026-11-12 20:06:04
1
To see more videos from user @conor_the_digger_driver, please go to the Tikwm